Alderon FWP with its hollow triple-wall construction provides good thermal (and sound) insulation properties. Above are tested sample data of insulating and conducting properties for comparison with other walls and panels.
The service temperature range of Alderon FWP is -20°C to 60°C; extra care should be taken when working with uPVC sheets at lower temperatures as uPVC is more susceptible to impact damage below 0°C.
Flammability
Alderon FWP is self-extinguishing without an external flame source and conforms to the highest ratings for plastic and composite materials. Under the UL94 Flammability Test, Alderon FWP is classified as V-0 low flammability.
Physical & Mechanical Properties
Test Method
Product Alderon FWP
Tensile Strength at Yield
ASTM D-638
30 Mpa
Elongation at Yield
ASTM D-638
15%
Hardness
ASTM D-2240
79
Modulus of Elasticity in Bending
ASTM D-790
750
When installing Alderon FWP, horizontal supporting beams should be applied every 1500 mm – 1800 mm in height and vertical beams at approximately 2000 mm span width.
Please note that mechanical strength may reduce over time if exposed to sunlight and chemicals; after several years (depending on site conditions), it is recommended to inspect the structural integrity of the panels.
Corrosion and Chemical Resistance
Test Method
Product Alderon FWP
Sulphuric Acid 40% at 60°C for 168 hours
ASTM D543-06
No Change
Nitric Acid 40% at 60°C for 168 hours
ASTM D543-06
No Change
Ammonia Gas at room temperature for 168 hours
ASTM D543-06
No Change
Alderon FWP has good chemical resistance to a wide range of chemicals, acids, and bases, especially rubber processing chemicals, paper-making chemicals, ammonia & methane gas/vapor from animal waste, fertilizer chemicals, galvanizing fumes, etc.
Installation Process
Click image to enlarge
Install the cladding module to the structure using roofing screws.
Attach the second cladding module using the tongue & groove system.
Alderon FWP with its hollow triple-wall construction provides good thermal (and sound) insulation properties. Above are tested sample data of insulating and conducting properties for comparison with other walls and panels.
The service temperature range of Alderon FWP is -20°C to 60°C; extra care should be taken when working with uPVC sheets at lower temperatures as uPVC is more susceptible to impact damage below 0°C.
Flammability
Alderon FWP is self-extinguishing without an external flame source and conforms to the highest ratings for plastic and composite materials. Under the UL94 Flammability Test, Alderon FWP is classified as V-0 low flammability.
Physical & Mechanical Properties
Test Method
Product Alderon FWP
Tensile Strength at Yield
ASTM D-638
30 Mpa
Elongation at Yield
ASTM D-638
15%
Hardness
ASTM D-2240
79
Modulus of Elasticity in Bending
ASTM D-790
750
When installing Alderon FWP, horizontal supporting beams should be applied every 1500 mm – 1800 mm in height and vertical beams at approximately 2000 mm span width.
Please note that mechanical strength may reduce over time if exposed to sunlight and chemicals; after several years (depending on site conditions), it is recommended to inspect the structural integrity of the panels.
Corrosion and Chemical Resistance
Test Method
Product Alderon FWP
Sulphuric Acid 40% at 60°C for 168 hours
ASTM D543-06
No Change
Nitric Acid 40% at 60°C for 168 hours
ASTM D543-06
No Change
Ammonia Gas at room temperature for 168 hours
ASTM D543-06
No Change
Alderon FWP has good chemical resistance to a wide range of chemicals, acids, and bases, especially rubber processing chemicals, paper-making chemicals, ammonia & methane gas/vapor from animal waste, fertilizer chemicals, galvanizing fumes, etc.
Installation Process
Click image to enlarge
Install the cladding module to the structure using roofing screws.
Attach the second cladding module using the tongue & groove system.